Sizing LiFePO4 Leisure Batteries for an 8-Hour Remote Workday in a Campervan
A worked load budget for laptop, monitor, router, satellite and fridge — then the maths that turns watt-hours into amp-hours, depth of discharge and days of autonomy.
Battery sizing goes wrong when people start with a product page instead of a load list. The reliable method is boring: list every device, multiply watts by hours, add losses, then convert to amp-hours with a realistic depth of discharge. Here is that method applied to a typical remote workday.
Step 1: Build the load budget
| Device | Watts | Hours | Wh/day |
|---|---|---|---|
| Laptop (USB-C PD, light work) | 30 | 8 | 240 |
| Starlink Mini | 35 | 8 | 280 |
| Travel router (always on) | 6 | 24 | 144 |
| Compressor fridge (duty cycled) | 15 avg | 24 | 360 |
| Phone, LED lights, roof fan | — | — | 60 |
| Subtotal | 1,084 |
Add about 6 % for DC-DC conversion and cable losses and you land near 1,150 Wh. If you power the laptop from an inverter instead of USB-C PD, add another 10–20 % plus inverter idle draw.
Step 2: Convert to amp-hours
LiFePO4 can safely deliver 90 % or more of its rated capacity, but keeping 10 % in reserve protects you from BMS cut-off in cold weather. The formula:
Required Ah = Daily Wh ÷ (System V × Usable DoD)
1,150 ÷ (12.8 × 0.9) ≈ 100 Ah — for a single day with zero charging.
Step 3: Plan for autonomy
Cloudy days, forest pitches and two-day stationary stints happen. Two days of autonomy is a sensible minimum for full-time remote work, which points to a 200 Ah bank. If you have 300–400 W of roof solar and drive most days with a DC-DC charger, 200 Ah will rarely drop below 50 %.
Step 4: Check the charge side
- Solar: 400 W of panels yields roughly 1,200–1,600 Wh on a clear summer day, 300–500 Wh in winter.
- Alternator: a 30 A DC-DC charger adds about 380 Wh per hour of driving.
- Shore power: a 20–40 A mains charger refills a 200 Ah bank in an afternoon.
Common mistakes
- Using laptop charger label wattage (e.g. 96 W) instead of measured average draw.
- Forgetting the router and fridge run 24 hours, not 8.
- Ignoring cold: LiFePO4 must not be charged below 0 °C without heating.
Use the Watt-Hour & Battery Drain Calculator to plug in your own devices.
Safety note: figures are typical planning values. Confirm ratings on your hardware labels and follow local electrical and radio regulations. When in doubt, have DC installations checked by a qualified auto-electrician.