Campervan Electrical & 12V/24V Wi-Fi Power Systems

Sizing LiFePO4 Leisure Batteries for an 8-Hour Remote Workday in a Campervan

A worked load budget for laptop, monitor, router, satellite and fridge — then the maths that turns watt-hours into amp-hours, depth of discharge and days of autonomy.

Example remote-work day: where the watt-hours goExample remote-work day: where the watt-hours goCompressor fridge (24 h)360 WhStarlink Mini (8 h)280 WhLaptop 14" (8 h)240 WhTravel router (24 h)144 WhPhone, lights, fan60 WhConversion losses (~6 %)65 WhTotal ≈ 1,150 Wh. Size the bank for at least two such days.
Schematic #3 — Sizing LiFePO4 Leisure Batteries for an 8-Hour Remote Workday in a Campervan

Battery sizing goes wrong when people start with a product page instead of a load list. The reliable method is boring: list every device, multiply watts by hours, add losses, then convert to amp-hours with a realistic depth of discharge. Here is that method applied to a typical remote workday.

Step 1: Build the load budget

DeviceWattsHoursWh/day
Laptop (USB-C PD, light work)308240
Starlink Mini358280
Travel router (always on)624144
Compressor fridge (duty cycled)15 avg24360
Phone, LED lights, roof fan——60
Subtotal1,084

Add about 6 % for DC-DC conversion and cable losses and you land near 1,150 Wh. If you power the laptop from an inverter instead of USB-C PD, add another 10–20 % plus inverter idle draw.

Step 2: Convert to amp-hours

LiFePO4 can safely deliver 90 % or more of its rated capacity, but keeping 10 % in reserve protects you from BMS cut-off in cold weather. The formula:

Required Ah = Daily Wh ÷ (System V × Usable DoD)

1,150 ÷ (12.8 × 0.9) ≈ 100 Ah — for a single day with zero charging.

Step 3: Plan for autonomy

Cloudy days, forest pitches and two-day stationary stints happen. Two days of autonomy is a sensible minimum for full-time remote work, which points to a 200 Ah bank. If you have 300–400 W of roof solar and drive most days with a DC-DC charger, 200 Ah will rarely drop below 50 %.

Step 4: Check the charge side

  • Solar: 400 W of panels yields roughly 1,200–1,600 Wh on a clear summer day, 300–500 Wh in winter.
  • Alternator: a 30 A DC-DC charger adds about 380 Wh per hour of driving.
  • Shore power: a 20–40 A mains charger refills a 200 Ah bank in an afternoon.

Common mistakes

  • Using laptop charger label wattage (e.g. 96 W) instead of measured average draw.
  • Forgetting the router and fridge run 24 hours, not 8.
  • Ignoring cold: LiFePO4 must not be charged below 0 °C without heating.

Use the Watt-Hour & Battery Drain Calculator to plug in your own devices.

Safety note: figures are typical planning values. Confirm ratings on your hardware labels and follow local electrical and radio regulations. When in doubt, have DC installations checked by a qualified auto-electrician.